The Effect of Positional Movement of a Semiflexible Applicator on Dose Distrubutions in Low Dose Rate Brachytherapy for Cervical Carcinoma

Tarih
2010
Yazar
Tore, Gokhan
Okutan, Murat
Alas, Rusen Cosar
Kemikler, Gönül
Disci, Rian
Kucucuk, Seden
Aslay, Isik
Üst veri
Tüm öğe kaydını göster
Özet
Objective: Current study aims to detect the movements of a semiflexible applicator (TORE's applicator) in the first 24 hours and to analyze its effect on the calculated point A, bladder and rectum doses in low dose rate brachytherapy (LDR-BT) applications. Material and Methods: Eighty films were evaluated on 18 cervical carcinoma patients (20 applications) who were treated with curative radiotherapy. The comparison of the reference points and doses at critical organs were performed by using a reference axis which was fixed to bony landmarks in the pelvis. To evaluate the movement of the applicator, distance of the upper point and lower point of the tandem to the reference axis were measured. Additionally, the angular deviation of the applicator was tested. Results: The movements of the upper point and lower point of the tandem in x, y, z axes were 5.30 +/- 6.33 mm, 2.80 +/- 2.24 mm, 6.65 +/- 8.33 mm and 3.45 +/- 4.32 mm, 3.75 +/- 3.59 mm, 3.05 +/- 3.08 mm, respectively. The mean differences were 3.30 +/- 2.99 degrees in alpha-angle and 5.65 +/- 4.76 degrees in beta-angle. The mean percent dose changes in point A, bladder and rectum were 1.5 +/- 1.2%, 3.7 +/- 3.1%, 4.4 +/- 4.0%, respectively. Conclusion: Our study demonstrates that there are some movements of the applicator during LDR-BT, however these movements do not result in significant dose changes in target volumes and critical organs. Therefore, positional correction is not required. In conclusion, CT-compatible TORE's applicator that allows an advantage for CT-based 3D planning is useful and safe for brachytherapy.
Bağlantı
http://hdl.handle.net/20.500.12627/57567
https://doi.org/10.5336/medsci.2009-14229
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV