• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Optimal imaging of cortico-muscular coherence through a novel regression technique based on multi-channel EEG and un-rectified EMG

Tarih
2011
Yazar
NOLTE, Guido
Bayraktaroglu, Zübeyir
LOSCH, Florian
CURIO, Gabriel
NIKULIN, Vadim V.
VON CARLOWITZ-GHORI, Katherina
Üst veri
Tüm öğe kaydını göster
Özet
Cortico-muscular coherence (CMC) reflects interactions between muscular and cortical activities as detected with EMG and EEG recordings, respectively. Most previous studies utilized EMG rectification for CMC calculation. Yet, recent modeling studies predicted that EMG rectification might have disadvantages for CMC evaluation. In addition, previously the effect of rectification on CMC was estimated with single-channel EEG which might be suboptimal for detection of CMC. In order to optimally detect CMC with un-rectified EMG and resolve the issue of EMG rectification for CMC estimation, we introduce a novel method, Regression CMC (R-CMC), which maximizes the coherence between EEG and EMG. The core idea is to use multiple regression where narrowly filtered EEG signals serve as predictors and EMG is the dependent variable. We investigated CMC during isometric contraction of the abductor pollicis brevis muscle. In order to facilitate the comparison with previous studies, we estimated the effect of rectification with frequently used Laplacian filtering and C3/C4 vs. linked earlobes. For all three types of analysis, we detected CMC in the beta frequency range above the contralateral sensorimotor areas. The R-CMC approach was validated with simulations and real data and was found capable of recovering CMC even in case of high levels of background noise. When using single channel data, there were no changes in the strength of CMC estimated with rectified or un-rectified EMG in agreement with the previous findings. Critically, for both Laplacian and R-CMC analyses EMG rectification resulted in significantly smaller CMC values compared to un-rectified EMG. Thus, the present results provide empirical evidence for the predictions from the earlier modeling studies that rectification of EMG can reduce CMC. (C) 2011 Elsevier Inc. All rights reserved.
Bağlantı
http://hdl.handle.net/20.500.12627/54189
https://doi.org/10.1016/j.neuroimage.2011.04.071
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV