• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Rapid and sensitive determination of antifouling organotin compounds in sediments using Gas chromatography with Tandem MS (GC - MSMS / GC - QTOF)

Yazar
Cetinturk, Kartal
Unlu, Selma
Üst veri
Tüm öğe kaydını göster
Özet
Organotin compounds are causing deterioration effect on non-targeted aquatic species in the environment, such as shell anomalies in oysters and imposex in gastropods, even at concentrations as low nanograms per litre. Specific analytical methods have been developed for different environmental matrices. Analysis of organotin compounds in sediment because of hydrophobic properties and tend to adsorb onto particulate matter is valuable for assessing the environmental distribution and fate. Therefore, in this study, a rapid, reliable, sensitive and effective method developed for quantification and identification of antifouling organotin butyl- and phenyltin compounds in sediment samples by using Gas chromatography with Tandem MS detector (GC-MSMS and GC-QTOF). The method is based on the single extraction step followed by GC-MSMS and GC-QTOF detection. The sample extraction steps were decreased for low labour laboratory costs and time-consuming. Not only the extraction procedure but instrumental method parameters were carefully optimised in order to increase sensitivity and precision. The QTOF system with the help of mass accuracy and mass resolution showed a good sensitivity and precision to analyse sediment samples. The isotopic disturbance and utilisation isotopic space for confirmation of organotin compounds have been scrutinised in GC-QTOF. GC Triple Quadrupole (GC-MSMS) system also utilised as a secondary confirmation method for organotin compound analysis. Additionally, the sensitivity of both MS detectors under the matrix effect was investigated. The recoveries of extraction were in the range of 82-106%. The acquired results have shown that the concentration range in 10-250 ppb (ng/ml) level was denoted good linearity (r(2) = 0.9725-0.9983). Moreover, limits of detection (LOD) for both butyl and phenyl fractions of organotin compounds were ranged between 0.23 and 22.11 pg/ml. Consequently, the developed method successfully was applied to certificated reference material (BCR - 462) and the targeted organotin compounds in a real marine/harbour sediment sample.
Bağlantı
http://hdl.handle.net/20.500.12627/4838
https://doi.org/10.1080/03067319.2020.1769089
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV