• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Clinical Utility of Tc-99m MIBI SPECT/CT for Preoperative Localization of Parathyroid Lesions

Tarih
2017
Yazar
Kuyumcu, Serkan
Unal, Seher Nilgun
Gecer, Mehmet Fatih
Erbil, Yesim
Ozcinar, Beyza
Ozkan, Zeynep Gözde
Sanli, Yasemin
Giles, Yasemin Senyurek
Üst veri
Tüm öğe kaydını göster
Özet
We aimed to demonstrate the role of SPECT/CT in preoperative localization of parathyroid lesions in patients with hyperparathyroidism who had technetium-99m (Tc-99m) methoxyisobutylisonitrile (MIBI) dual-phase parathyroid scintigraphy. We evaluated retrospectively the scintigraphic data of 103 patients who had parathyroidectomy after Tc-99m MIBI dual-phase parathyroid scintigraphy with SPECT/CT. The planar and SPECT/CT images were evaluated separately to determine their efficacy in localizing parathyroid lesions. These results were then compared with surgical data. There were 84 female and 19 male patients whose mean age was 54 +/- 12 years. A total of 115 parathyroid lesions in 103 patients were resected during operations. In 87 patients, with both planar and SPECT/CT images, a total of 100 lesions could be detected correctly. In 11 patients, only SPECT/CT images could show 13 subcentimetric lesions. In three patients, three lesions were evaluated as parathyroid lesions both with planar and SPECT/CT images, but according to histopathologic evaluation, they came out to be nonparathyroidal lesions. In two patients, two parathyroid lesions could not be detected preoperatively neither with planar nor with SPECT/CT images. The lesion-based sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 87 %, 99 %, 97.1 %, 95.3 %, and 95.8 % for planar images and 98.3 %, 99 %, 97.4 %, 99.4 %, and 98.8 % for SPECT/CT images, respectively. Tc-99m MIBI parathyroid scintigraphy should be a diagnostic modality of choice in preoperative evaluation of patients with hyperparathyroidism. SPECT/CT has an incremental value both in demonstrating subcentimetric lesions and in accurately localizing lesions anatomically.
Bağlantı
http://hdl.handle.net/20.500.12627/45425
https://doi.org/10.1007/s12262-016-1489-7
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV