• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Early detection of E. coli and total coliform using an automated, colorimetric and fluorometric fiber optics-based device

Tarih
2019
Yazar
Koydemir, Hatice Ceylan
Ozcan, Aydogan
Tok, Sabiha
de Haan, Kevin
Tseng, Derek
Usanmaz, Can Firat
Üst veri
Tüm öğe kaydını göster
Özet
Lack of access to clean water is a major global issue that affects millions of people worldwide. Drinking contaminated water can be extremely hazardous, so it is imperative that it is tested sufficiently. One method commonly used to determine the quality of water is testing for both E. coli and total coliform. Here, we present a cost-effective and automated device which can concurrently test drinking water samples for both E. coli and total coliform using an EPA-approved reagent. Equipped with a Raspberry Pi microcontroller and camera, we perform automated periodic measurements of both the absorption and fluorescence of the water under test over 24 hours. In each test, 100 mL of the water sample is split into a custom designed 40-well plate, where the transmitted blue light and the fluorescent light (under UV excitation) are collected by 520 individual optical fibers. Images of these fiber outputs are then acquired periodically, and digitally processed to determine the presence of the bacteria in each well of the 40-well plate. We demonstrate that this cost-effective device, weighing 1.66 kg, can automatically detect the presence of both E. coli and total coliform in drinking water within similar to 16 hours, down to a level of one colony-forming unit (CFU) per 100 mL. Furthermore, due to its automated analysis, this approach is also more sensitive than a manual count performed by an expert, reducing the time needed to determine whether the water under test is safe to drink or not.
Bağlantı
http://hdl.handle.net/20.500.12627/37087
https://doi.org/10.1039/c9lc00652d
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV