• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Bone marrow radiation dosimetry of high dose I-131 treatment in differentiated thyroid carcinoma patients

Tarih
2016
Yazar
Ereees, S.
Uysal, B.
Gumuser, G.
Parlak, Y.
Demir, Mustafa
Cavdar, I.
Sayit, E.
Koc, M.
Kaya, G. Capa
Üst veri
Tüm öğe kaydını göster
Özet
Background: Radiation absorbed dose to the red bone marrow, a critical organ in the therapy of thyroid carcinoma, is generally kept below 2 Gy for non-myeloablative therapies. The aim of this study was to calculate bone marrow radiation dose by using MIRDOSE3 package program and to optimize the safe limit of activity to be administered to the thyroid cancer patients. Materials and Methods: In this study, 83 thyroid cancer patients were divided into 3 groups based on the amount of activity administered into the body. In the groups, 3700 MBq, 5550 MBq and 7400 MBq activities were used respectively. The curves of time-activity were drawn from blood samples counts and effective half-life and residencetime were calculated. Correlations of bone marrow radiation dose and radioiodine effective half-life were determined as a function of administered activity via ANOVA test. Tg levels and tumour diameters were compared using Spearman's correlation. Results: The effective half-lives of I-131 for three groups of whole-body, receiving 3700 MBq, 5550 MBq and 7400 MBq were calculated as 20.57 +/- 5.4, 17.8 +/- 5.8 and 18.7 +/- 3.9 hours, respectively. The average bone marrow doses for 3 groups of patients were 0.32 +/- 0.08 Gy, 0.42 +/- 0.14 Gy and 0.60 +/- 0.24 Gy, respectively. Conclusion: It was concluded that, the bone marrow dose to the patients still remains within the recommended level even a 9 er administering an activity of 7400 MBq of I-131 to the patients.
Bağlantı
http://hdl.handle.net/20.500.12627/36860
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV