• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Injectable Calcium Phosphate Cement as a Bone-Graft Material Around Peri-implant Dehiscence Defects: A Dog Study

Tarih
2008
Yazar
JANSEN, John A.
Arisan, Volkan
Ozdemir, Tayfun
Ozer, Kursat
ANIL, Ata
Üst veri
Tüm öğe kaydını göster
Özet
Purpose: Peri-implant dehiscence defects occur frequently after dental implant placement. Various graft materials and techniques are proposed for treatment. In this study, an injectable calcium phosphate cement (Augmentech, Wetzlar, Germany) applied to a peri-implant defect was investigated. Materials and Methods: Standardized buccal dehiscence defects (5.8 x 3.8 mm) were surgically created after implant site preparation in the right proximal tibiae of 5 beagle dogs. Fifteen stepped cylindrical implants (13 x 3.8 mm diameter) were inserted (3 per dog), and Augmentech injectable calcium phosphate cement was injected into the dehiscences. The bone at the distal side of the implant was left intact to serve as a control. Postsurgically, each dog received double staining of 2 fluorescent labels for estimation of bone cell activity at baseline and after 11 weeks of heating, The animals were sacrificed after 12 weeks. Dissected blocks were processed for histologic, histomorphometric, and fluorescence microscopic analysis, ie, percentage of bone-to-implant contact (BIC) and percentage linear bone height (LBH) were measured. Student t and Mann Whitney U tests were used for statistical analysis (P < .05). Results: Healing was uneventful in all dogs. Augmentech injectable calcium phosphate cement showed good space maintenance and osteoconductive properties with no foreign body reaction. BIC was 34.42 (+/- 19.88) and 37.00 (+/- 21.33) (P = .375), while LBH was 84.23 (+/- 19.73) and 96.10 (+/- 6.66) (P = .125) for test and control sites, respectively. Conclusion: Within the limits of the present study, it was concluded that Augmentech injectable calcium phosphate cement may be a suitable material for the treatment of buccal dehiscence defects around dental implants. INT J ORAL MAXILLOFAC IMPLANTS 2008;23:1053-1062.
Bağlantı
http://hdl.handle.net/20.500.12627/22431
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV