Clinical efficacy of the Vector system in excess cement removal during fixed prosthodontic treatment

Tarih
2008
Yazar
Akguengoer, Goekhan
Aydin, Murat
Issever, Halim
Sen, Deniz
Üst veri
Tüm öğe kaydını göster
Özet
Objective: To evaluate the clinical effectiveness of the Vector system (Durr Dental) in excess cement removal from subgingival margins during fixed prosthodontic treatment. Method and Materials: A total of 41 subjects, each in need of a minimum of 2 metal-ceramic crowns in different quadrants, took part in this study. Altogether, 156 abutment teeth were randomly assigned into 2 groups: In one group, excess cement was removed with the Vector system after cementation of provisional and permanent restorations, while in the other group, handheld instruments were used for this procedure. The clinical parameters Plaque Index (PI), Gingival Index (GI), and probing pocket depth (PPD) were recorded at baseline, at the same appointment after cementation of provisional restorations, 2 weeks later after cementation of permanent restorations, and 3 weeks after final cementation. Results: Both the Vector system and the handheld instruments were able to reduce PPD and PI significantly at 2 and 5 weeks, but no significant differences could be demonstrated between the groups. Regarding GI, significant reductions were found at 2 and 5 weeks for the Vector group (P < .001), whereas for the handheld instrument group, the only significant difference could be demonstrated at 5 weeks (P = .001). Significant differences between the groups occurred at 2 weeks (P = .003) and 5 weeks (P = .002), with the Vector group having the greatest reduction in GI. Conclusion: Although similar reductions in Plaque Index and probing pocket depths were observed with both the Vector system and handheld instruments, the Vector system produced a significantly greater benefit in reducing Gingival Index.
Bağlantı
http://hdl.handle.net/20.500.12627/22032
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV