• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Impact of Multimodality Imaging on the Diagnosis of Left Ventricular Apical Thrombus in Patients After Anterior Myocardial Infarction

Tarih
2022
Yazar
Cevik, Erdem
Demirkiran, Ahmet
Demir, Ali Aslan
BARMAN, HASAN ALİ
Dursun, Memduh
Bugra, Melike Zehra
ATICI, ADEM
Asoglu, Ramazan
Üst veri
Tüm öğe kaydını göster
Özet
Background: The presence of the left ventricle (LV) apical thrombus is one of the most critical complications of anterior myo-cardial infarction (MI). Due to the high risk of systemic embolization, the determination of LV apical thrombus (LVAT) is essen-tial. We aimed to compare the two-dimensional echocardiography (2DE), contrast-2DE and real-time three-dimensional echocardiography (RT-3DE) in the diagnosis of LVAT and determine which imaging modality is superior. Methods: The study was designed as a prospective cohort study, and 161 patients were included. Patients with low ejection fraction (< 40%) and LV apical wall motion abnormality (severe hypokinetic, akinetic or dyskinetic) were included. 2DE, con-trast-2DE, RT-3DE, and magnetic resonance imaging (MRI) were performed on all patients within one month after anterior MI. Results: Transthoracic 2DE detected thrombi in 29 patients, contrast-2DE detected thrombi in 33 patients, RT-3DE detected thrombi in 32 patients, and MRI detected thrombi in 28 patients. While MRI is accepted as the gold standard for non-invasive imaging, the specificity of detecting thrombus with 2DE is 90%, and the sensitivity is 57%, contrast-2DE had 82% sensitivity and 92% specificity for the detection of LVAT. The specificity for detecting thrombus with RT-3DE is 93%, and the sensitivity is 85%. Accuracy was 84%, 90% and 92% with 2DE, contrast-2DE and RT-3DE, respectively. Conclusions: We found that RT-3DE was more sensitive and more specific than 2DE and contrast-2DE in the diagnosis of LVAT. The diagnostic accuracy of RT-3DE was higher than 2DE and contrast-2DE for LVAT.
Bağlantı
http://hdl.handle.net/20.500.12627/182790
https://doi.org/10.1016/j.amjms.2021.06.028.
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV