In Vitro Comparison of the Accuracy of Conventional Impression and Four Intraoral Scanners in Four Different Implant Impression Scenarios

Tarih
2022
Yazar
Alpkilic, Dilara Seyma
Deger, Sabire
Üst veri
Tüm öğe kaydını göster
Özet
Purpose: The aim of this study was to compare the trueness and precision of four intraoral scanners (IOSs) and splinted open-tray conventional implant impression (SOCI) in partial and total edentulism. Materials and Methods: Four gypsum models (Model A-implants at mandibular right second molar, right second premolar, and right canine; Model B- implants at mandibular right canine, left central incisor, and left canine; Model C-implants at mandibular right second molar, right second premolar, right canine, left central incisor, and left canine; and Model D-implants at mandibular right second molar, right second premolar, right canine, left central incisor, left canine, left second premolar, and left second molar) were prepared, and four different IOSs (Aadva IOS, CS 3600, Trios 3, and Emerald) and one polyvinyl siloxane (PVS) were used. Reference models were digitized with a high-resolution industrial scanner, and data were superimposed. Root mean square (RMS) values were calculated by software and defined as deviation values after superimposition. The one-way analysis of variance (ANOVA) test and Tukey honest significant difference (HSD) test were performed to analyze the data (P < .05). Results: For Models A and B, the truest impressions were made with Aadva, followed by CS 3600, PVS, Trios 3, and Emerald, respectively, while for Model C, the truest impressions were made with CS 3600, followed by Aadva, PVS, Trios 3, and Emerald, and for Model D, the truest impressions were made with Aadva, followed by CS 3600, PVS, Emerald, and Trios 3 (P .05). There was no statistical difference between groups for precision in Models A, B, and C (P .05); however, PVS showed lower precision values than other groups in Model D (P < .05). Conclusion: In partial edentulism, IOSs are true and precise as SOCI except Emerald. However, the trueness of IOSs is not favorable in total edentulism cases. SOCI with PVS in total edentulism treated with implants is less precise than IOSs. Int J Oral Maxillofac Implants 2022;37: 39-48. doi: 10.11607/jomi.9172
Bağlantı
http://hdl.handle.net/20.500.12627/181413
https://doi.org/10.11607/jomi.9172
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV