• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Transcatheter Closure of Perimembranous Ventricular Septal Defects using Nit-Occlud((R)) L VSD Coil: Early and Mid-Term Results

Tarih
2014
Yazar
Odemis, Ender
Ozyilmaz, Isa
Ergul, Yakup
Tanidir, I. Cansaran
Guzeltas, Alper
BAKIR, İhsan
Saygi, Murat
Üst veri
Tüm öğe kaydını göster
Özet
Our objective was to investigate the short- and mid-term results of transcatheter ventricular septal defect (VSD) closure with the Nit-Occlud(A (R)) L VSD coil. Retrospective data collection study. Data were collected from 20 patients who underwent transcatheter VSD closure with the Nit-Occlud(A (R)) L VSD coil device between October 2011 and June 2013. The mean age of the study subjects was 7.3 +/- A 4.0 years, and the mean weight was 25.7 +/- A 11.8 kg. The distance between the defect and the aortic valve, measured using angiography, was an average of 5.1 +/- A 2.0 mm, and the left ventricular opening averaged 8.2 +/- A 2.1 mm. The mean value of the Q (p)/Q (s) ratio was 1.7 +/- A 0.4. Intravascular hemolysis developed in the first few hours after the procedure in three patients. In one of these cases, despite medical treatment and the implantation of a detachable coil placed into the Nit-Occlud(A (R)) device transcatheterly, hemolysis persisted. This device was removed and the VSD was closed surgically. In the other two cases, although the residual shunt persisted on echocardiography, the hemolysis regressed spontaneously. There were no rhythm problems or other complications during the follow-up period of 12.3 +/- A 6.6 months. In the selected cases, for the transcatheter treatment of VSD, the Nit-Occlud(A (R)) L VSD coil device can be used. When compared with other VSD closure devices, there was no development of a permanent atrioventricular block, which is an important advantage. However, patients with a residual shunt should be monitored closely for the development of hemolysis during the first few hours.
Bağlantı
http://hdl.handle.net/20.500.12627/179046
https://doi.org/10.1007/s00246-013-0860-8
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV