Scanning electron microscopy analysis of conventional and controlled-memory nickel titanium files before and after multi-uses in root canals

Yazar
Armagan, Safa
Haznedaroglu, Faruk
Üst veri
Tüm öğe kaydını göster
Özet
The current study aimed to examine changes in the physical properties of conventional and CM nickel-titanium instruments after repeated clinical use, disinfection-sterilization processes, using scanning electron microscopy (SEM). Sixty extracted mandibular molar mesial roots were used in this ex vivo study. The 60 teeth underwent final apical shaping (#25/.06) by the Revo-S SU (Revo-S Group: #25/.06; Micromega; n = 10) and Hyflex CM (Hyflex CM group: #25/.06; Coltene-Whaledent; n = 10) groups. One instrument of each group was used to shape six different teeth (Revo-S SU in 3 MB and 3 ML canals, and Hyflex CM in 3 MB and 3 ML canals), sequentially. The physical changes evident on the surfaces of the files after sequential use and sterilization processes were analyzed by SEM after the first, third, and sixth use. The first SEM examination was performed immediately after removal from the packages. Following first SEM examination, the files were sterilized before the first use as would be customary in practice. Qualitative evaluations were made by two evaluators, according to the following criteria: tip deformation, cutting edge deformation, debris, and microfracture. Revo-S showed a significant difference in cutting edge deformation, tip deformation, and microcrack formation, as compared to Hyflex CM. There was no significant difference between the groups in debris with the increasing number of uses. In this study, Hyflex CM (CM nickel-titanium) files showed better performance in terms of deformation and microcrack formation as the number of uses increased than did Revo-S (conventional nickel-titanium) files.
Bağlantı
http://hdl.handle.net/20.500.12627/1783
https://doi.org/10.1002/jemt.23691
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV