Automatic Detection of CAP on central and fronto-central EEG leads via Support Vector Machines
Yazar
Mendez, Martin O.
Parrino, Liborio
Bianchi, Anna M.
Terzano, Mario G.
Mariani, Sara
Grassi, Andrea
Üst veri
Tüm öğe kaydını gösterÖzet
The aim of this study is to implement a high-accuracy automatic detector of the Cyclic Alternating Pattern (CAP) during sleep. EEG data from four healthy subjects were used. Both the C4-A1 and the F4-C4 leads were analyzed for this study. Seven features were extracted from each of the two leads and two separate studies were performed for each set of descriptors. For both sets, a Support Vector Machine was trained and tested on the data with the Leave One Out cross-validation method. The two final classifications obtained on the two sets were merged, by considering a CAP A phase scored only if it had been recognized both on the central and on the frontal lead. The length of the A phase was then determined by the result on the fronto-central lead. This method leads to encouraging results, with a classification sensitivity on the whole dataset equal to 73.82%, specificity equal to 85.93%, accuracy equal to 84,05% and Cohen's kappa equal to 0.50.
Koleksiyonlar
- Bildiri [64839]