Highly sensitive and selective rGO based Non-Enzymatic electrochemical sensor for propamocarb fungicide pesticide detection
Yazar
Tasaltin, Cihat
Baytemir, Gulsen
Tasaltin, Nevin
KARAKUŞ, SELCAN
Üst veri
Tüm öğe kaydını gösterÖzet
In this study, reduced graphene oxide (rGO) was prepared using a green ultrasonic microwave assisted method and investigated rGO based non-enzymatic electrochemical sensor for detecting a synthetic fungicide as a propamocarb (PM) pesticide. The rGO-based sensor exhibited rapid response within 1 min, low detection limit of 0.6 mu M and wide linear range of (1-5) mu M with a high sensitivity of 101.1 mu A mu M- 1 cm-2 for PM. Besides this, the sensor detected the propamocarb pesticide on the real cucumber sample with high sensitivity in the concentration range of (1-5) mu M within a 1-minute cycle. The sensor is highly selective against propamocarb pesticide. The prepared non-enzymatic electrochemical sensor exhibited high sensitivity, high selectivity, reproducibility, and rapid response.
Koleksiyonlar
- Makale [92796]