• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Bruch's membrane opening-minimum rim width: An alternative OCT biomarker study for multiple sclerosis

Yazar
Gunduz, Tuncay
Eraksoy, Mefkure
Kurtuncu, Murat
Gedik, Ali Ceyhun
Kartal, Selva Nur Cukurova
Ozbilen, Kemal Turgay
Üst veri
Tüm öğe kaydını göster
Özet
Purpose: Bruch's membrane opening-minimum rim width (BMO-MRW) and RNFL measured using anatomic positioning system (APS-RNFL) are novel OCT methods and remained unexplored in MS patients. To investigate the novel parameters of spectral-domain OCT as an alternative biomarker in patients with multiple sclerosis (MS). Methods: Retrospective cohort study; participants consisted of relapsing-remitting MS (RRMS) patients and healthy controls (HC). Eyes were classified according to the presence of MS and previous optic neuritis (ON). Measurements of standard peripapillary RNFL (S-RNFL), BMO-MRW, and APS-RNFL were performed. Result: A total of 244 eyes of 122 participants (MS-patients: 63, HC: 59) were included in the study. Fifty-one eyes had a history of previous ON. In almost all measured parameters, neuroretinal rim thicknesses were observed the thinnest in eyes with ON history between all subgroups. S-RNFL and APS-RNFL techniques showed the difference in neuroretinal rim thickness in all three subjects (ON+, ON-, and HC). However, BMO-MRW, on the other hand, could not distinguish between ON(-) patients and HC. The relationship between OCT parameters and EDSS were observed only in eyes with an ON history in all three techniques. A meaningful model with 78% accuracy was obtained by using only the OCT parameters as risk factors. In the ROC analysis, no parameters were found to have acceptable high sensitivity and specificity. BMO-MRW was statistically weaker in every aspect than other RNFL techniques. Conclusion: The novel APS-RNFL technique appears to be a bit more reliable alternative to S-RNFL technique to support therapeutic decision-making in MS. BMO-MRW has not been found as a successful alternative to S-RNFL.
Bağlantı
http://hdl.handle.net/20.500.12627/174836
https://doi.org/10.1177/1120672121996638
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV