• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Cemented radial head arthroplasty: Does radiographic loosening have an effect on clinical and functional outcomes? Average 10 years' results

Yazar
ERŞEN, Ali
Demirhan, Mehmet
Bayram, Serkan
ATALAR, Ata Can
Pehlivanoglu, Tuna
Üst veri
Tüm öğe kaydını göster
Özet
Purpose The aim of this study was to evaluate the possible effect of radiographic loosening on clinical and functional outcomes, while presenting the mid-term radiographic and functional outcomes of cemented, monopolar RHA applied to patients with comminuted radial head fractures. Methods We performed a retrospective study by evaluating the records of patients who were diagnosed in a single center with radial head fractures between 2001 and 2013. Twenty-six patients with comminuted radial head fractures with a mean age of 48.9 and a mean follow-up time of 132.2 months were included. The radiographic evaluation was performed by assessing peri-prosthetic radiolucent lines around the stem to evaluate loosening, while the clinical evaluation was performed by utilizing elbow range of motion (ROM), Mayo elbow performance score (MEPS), Oxford elbow score (OES) and quick-DASH scores. Results 13 patients (Group 1) with peri-prosthetic stem lucency were defined as radiographic loosening (50%), while the remaining 13 patients (Group 2) were not detected to have stem lucency. One patient in group 1 also had concomitant pain and underwent removal of the prosthesis, while 12 patients (92.3%) remained pain-free. On the latest follow-up visit, there was no significant difference between the groups regarding ROM, MEPS, OES and quick-DASH scores. Conclusions Within ten years following surgery, half of the patients with radial head prostheses were noted to show radiographic signs of loosening which did not have any major negative effect in terms of clinical-functional outcomes and quality of life, except requiring the removal of the implant in one patient.
Bağlantı
http://hdl.handle.net/20.500.12627/172820
https://doi.org/10.1007/s00590-021-03129-3
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV