• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

GRAding of functional and anatomical response to DExamethasone implant in patients with Diabetic Macular Edema: GRADE-DME Study

Tarih
2021
Yazar
Lupidi, Marco
Rodriguez-Valdes, Patricio J.
Rehak, Matus
Zur, Dinah
Sala-Puigdollers, Anna
Fraser-Bell, Samantha
Chhablani, Jay
Lains, Ines
Chaikitmongkol, Voraporn
Fung, Adrian T.
Okada, Mali
Unterlauft, Jan Darius
Smadar, Lital
Loewenstein, Anat
Iglicki, Matias
Busch, Catharina
Cebeci, Zafer
Üst veri
Tüm öğe kaydını göster
Özet
To analyze functional and anatomical response patterns to dexamethasone (DEX) implant in diabetic macular edema (DME), to describe proportion of responders and non-responders, and to propose a new DME grading system. Retrospective, multicenter, observational cohort study. Naive and non-naive DME patients were treated with DEX, with visual acuity (VA)>= 0.2 logMAR and central subfield thickness (CST) of >= 300 mu m. Functional and anatomical responses were graded after 2 and 4 months, and categorized as early and stable improvement, early and progressive improvement, pendular response, delayed improvement, and persistent non-response. 417 eyes were included (175 treatment naive eyes). Compared to non-naive eyes, naive eyes showed a very good functional response (VA gain >= 10 letters) more frequently after 2 and 4 months (56% and 57% [naive] vs. 33% and 28% [non-naive], p<0.001). A VA gain<5 letters (non-response) after 2 and 4 months was seen in 18% and 16% of naive eyes, and in 49% and 53% of non-naive eyes (p<0.001). A lack of anatomical response was rare in both groups, but more frequently in non-naive eyes (12% vs. 4%, p=0.003). Functionally and anatomically, naive eyes showed most frequently an early and stable improvement (functionally: 77/175 44%; anatomically: 123/175 eyes, 70%). Most non-naive eyes experienced no significant improvement functionally (97/242 eyes, 40%), despite a mostly early and stable improvement anatomical response pattern (102/242 eyes, 42%). Functional but not anatomical response patterns were influenced by baseline VA. Naive and non-naive eyes show different functional and anatomical response patterns to DEX implant. Functional non-responders are rare in naive eyes, whereas anatomical non-response is unusual in both groups.
Bağlantı
http://hdl.handle.net/20.500.12627/171089
https://doi.org/10.1038/s41598-020-79288-w
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV