• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Staple-line reinforcement using barbed sutures in 1008 sleeve gastrectomies

Yazar
Ozgen, Gorkem
Yerdel, Mehmet Ali
Acunas, Bulent
Calikoglu, Ismail
Üst veri
Tüm öğe kaydını göster
Özet
Purpose Among various staple-line reinforcement methods applied during sleeve gastrectomy (SG), although data on full-thickness-continuous-suturing (FTCS) is nearly nil, it has been considered as potentially harmful. The safety/efficacy profile of FTCS is assessed. Methods All consecutive SGs completing 3-month follow-up were studied. Data on peri-operative parameters, complications, and follow-up were prospectively recorded. All reinforcements were completed by FTCS utilizing barbed suture. Super-super obese, secondary SGs, SGs performed in patients with prior anti-reflux surgery, and SGs performed with additional concomitant procedures were evaluated as "technically demanding" SGs. Student's t/chi-square tests were used as appropriate. Results Between January 2012 and July 2020, 1008 SGs (941 "primary-standard," 67 "technically demanding") were performed without mortality/venous event. Single leak occurred in a patient with sleeve obstruction (0.1%). Thirteen bleedings, 4 requiring re-surgery (0.4%), and 17 stenoses (1.7%) were encountered. Four stenoses were treated with gastric bypass (1 emergency), 6 by dilatation(s), and one required parenteral nutrition. Six patients with stenosis chose not to have any treatment. No statistically significant difference was observed in postoperative complications between "primary-standard" and "technically demanding" SGs (p > 0.05). The median follow-up was 44 months. The excess weight loss % at 5th year was 80.1%. Suturing added 28.4 +/- 6 minutes to the SG, 3 or fewer sutures were used to complete the reinforcement in > 95%. No mishap/complication occurred related to suturing. Conclusion FTCS produced excellent result in terms of leakage/hemorrhage with an acceptable stenosis rate at a low cost with half-an-hour increase in the operating time. In contrast to previous allegations, no harm attributable to stitching itself occurred.
Bağlantı
http://hdl.handle.net/20.500.12627/168939
https://doi.org/10.1007/s00423-021-02161-5
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV