Spectrophotometric Determination of Doxazosin Mesylate in Tablets by Ion-Pair and Charge-Transfer Complexation Reactions

Tarih
2009
Yazar
Barla, Asli
Aydodmup, Zeynep
Üst veri
Tüm öğe kaydını göster
Özet
Two accurate, easy spectrophotometric methods for the determination of doxazosin mesylate were described. The first method was based on the formation of ion-pair complexes with the acidic sulfophthalein dyes bromocresol purple (BCP) and bromophenol blue (BPB) in pH 3.3 and 4.5 citrate-phosphate buffer, respectively. The formed complexes were extracted into dichloromethane, and their absorbance was measured at 403 and 410 nm for BCP and BPB, respectively. The second method was based on the charge transfer reaction of the drug as an n-electron donor with either 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) or 7,7,8,8-tetracyanoquinodimethane (TCNQ) as pi-acceptors, to give colored radical anions. The absorbances of products were measured at 457 nm in acetonitrile and 838 nm in methanol for DDQ and TCNQ, respectively. Under the optimum reaction conditions, Beer's law was obeyed with a good correlation coefficient (r = 0.9997-0.9999) in the concentration ranges 3.0-18.0, 3.0-20.0,15.0-95.0, and 10.0-100.0 mu g/mL for the BCP, BPB, DDQ, and TCNQ methods, respectively. Limits of detection of the BCP, BPB, DDQ, and TCNQ methods were 0.314, 0.408,1.935, and 1.610 mu g/mL, respectively. The limits of quantification were 1.045,1.360, 6.449, and 5.367 mu g/mL, respectively. The parameters molar absorptivity, precision, accuracy, recovery, robustness, and stability constant were studied. The proposed methods were successfully applied for determination of the drug in tablets with good accuracy and precision. Statistical comparison of the results with those obtained by a reported method showed good agreement and indicated no significant difference in accuracy and precision.
Bağlantı
http://hdl.handle.net/20.500.12627/15892
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV