Interinstitutional Review of Slides for Forensic Pathology Types of Inconsistencies

Tarih
2010
Yazar
AKYILDIZ, ELİF ÜLKER
Albek, Emre
Korkmaz, Gulay
Ersoy, Gokhan
Üst veri
Tüm öğe kaydını göster
Özet
Because of the specific structure of forensic medicine in Turkey, reexamination of histopathologic specimens is a frequent practice. The aim of the present study is the assessment of microscopic diagnostic consistency in forensic pathology between different laboratories. Reports of the Council of Forensic Medicine between 2001 and 2004 were examined, and 150 cases with second pathologic examination were found. Results of histopathologic reports from peripheral laboratories were compared with those made by the Council pathologists with regard to diagnostic consistency. Consistency was assessed in 3 groups and 1 subgroup. Group 1, consistent and minor inconsistency; includes a major consistency subgroup. Group 2, major inconsistency, is the second diagnosis which is lethal; group 3, major inconsistency, is the first diagnosis which is lethal. The lung was found to be the organ with the highest frequency of diagnostic major inconsistency (group 2 and 3) and major consistency. Bronchopneumonia was the most common diagnosis. The brain had the highest frequency of intercenter diagnostic overall consistency (90.2%, group 1). Myocardial infarction was the diagnosis most frequently rejected on reevaluation (group 3). In conclusion, forensic pathology requires different experience than surgical ones. In cases of discrepancy between the anamnesis of the lethal event and pathologic findings, reevaluation of specimen is mandatory to avoid any diagnostic errors. Quality assurance systems with all include internal and external control mechanisms will improve the diagnostic reliability.
Bağlantı
http://hdl.handle.net/20.500.12627/146500
https://doi.org/10.1097/paf.0b013e3181deb863
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV