• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Over-The-Top Knot Placement Technique Enhances Tensile Stability of Tendon Repairs

Tarih
2010
Yazar
Kilicoglu, Onder
ÇETİK, ÖZGÜR
ÇIRPAR, MERİÇ
Dirikolu, Husnu
KALAYCIOĞLU, BARIŞ
ÖZTÜRK, LATİF
Turker, Mehmet
Üst veri
Tüm öğe kaydını göster
Özet
Background: Currently a major concern for the surgical treatment of Achilles tendon rupture repairs is the creation of stable enough fixation to allow early range of motion. It was documented that the weakest point in a suture loop is the knot. Thus, we hypothesized that moving the knot away from the repair junction (over-the-top Krackow technique) would increase the strength of the repair. Materials and Methods: Transected bovine tendons were repaired by the traditional Krackow and over-the-top Krackow techniques using four suture materials (Fiberwire Nos. 5 and 2, Ethibond Nos. 5 and 2). Tendons were cyclically tested at incremental loads beginning from 50 N until 5-mm gap formation. Then all tendons were loaded to failure. The number of cycles to 5-mm gapping, ultimate failure loads and knot slip were compared using t-test and Mann-Whitney tests (with Tukey corrections for multiple comparisons). Results: Mean number of cycles to 5-mm gapping did not reveal significant differences (p = 0.113) between repair groups. Mean failure load of tendons repaired by over-the-top Krackow technique were significantly higher (p < 0.0001) for all four paired groups than tendons repaired by traditional Krackow technique. Ethibond No. 5, No. 2, and Fiberwire No. 2 suture repairs with over-the-top configuration did not reveal any knot slip. Conclusion: Over-the-top Krackow technique increases the ultimate failure load of repaired tendons. But 5-mm gapping resistivity was not enhanced either by the technique or the suture material. Clinical Relevance: The knot itself is a stress-riser in the suture loop so we suggest that freeing it from tension by our modificiation may achieve more durable repairs.
Bağlantı
http://hdl.handle.net/20.500.12627/113518
https://doi.org/10.3113/fai.2010.1006
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV