• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
  •   Açık Erişim Ana Sayfası
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

The effect of Er:YAG laser and bulk filled composite type on marginal adaptation of class II cavities: an SEM analysis study

Tarih
2018
Yazar
Aykor, Arzu
Tuncer, Safa
Demirci, Mustafa
Ozel, Emre
TEKÇE, NESLİHAN
Üst veri
Tüm öğe kaydını göster
Özet
Purpose: To evaluate the effect of cavity preparation method (Er:YAG laser or diamond bur) and bulk-filled composite material type on marginal adaptation mesial occlusal (MO) class II cavities. Materials and Methods: Two-surface box cavities (4-mm proximal depth and 5-mm occlusal width) were prepared on 60 human mandibular molar teeth. Cavities were prepared using Er:YAG laser or diamond burs in an air-turbine hand-piece. All cavities were applied Single Bond Universal dentin bonding agent. The cavities were further subdivided into three subgroups according to the restorative material used; two bulk-filled composites [Filtek Bulk Fill Posterior (3M ESPE) and SonicFill 2 (Kerr)] and one traditional composite material Filtek Ultimate Universal Restorative (3M ESPE). Restorations were evaluated using scanning electron microscopy at x200 magnification for their adaptation to the approximal margins of the tooth. Results were analyzed using the two-way ANOVA and Tukey Post Hoc Test (p<0.05). Results: A total of 900 SEM figures were obtained from all groups. Filtek Bulk Fill Posterior, SonicFill 2, and Filtek Ultimate Universal Restorative exhibited statistically similar gapped margins. However, the lowest scores of gapped margins were observed with SonicFill 2 (4.22%). Conclusions: Completely gap-free margins were not obtained with any of the tested materials. Bulk-fill composite materials showed similar marginal adapatation compared with standard composite. Marginal adaptation of Er:YAG laser prepared cavities was more irregular and had more gaps, but was statistically similar to diamond bur-prepared cavities.
Bağlantı
http://hdl.handle.net/20.500.12627/112192
https://doi.org/10.1080/01694243.2018.1442283
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV